Dimensions
(W x H x D )
150 x 86 x 142 mm/ 5 7/8"x3 3/8"x5 1/2"
Safety Approval
Meets UL 1950, CSA 22.2 No.234, TUV IEC 950, FCC Class B, VDE Class B
Temperature
32°F ~122 °F ( 0~ 50°C)
Relative Humidity
Operating: 10~90% rh
Storage: 5%~90% rh
Over Power Protection
Peak power protected to between 110% to 125% of continuous rated power.
Over Voltage Protection
+5V:5.5-6.5V
Efficiency
60% at typical load
Input Current
10A@-48V DC input
Input Voltage
Normal 12VDC
Min.
9VDC
Max.
18VDC
Input Amp
37 A
DC Output
V1
+5V
|
Max. Load |
25A |
|
Min. Load |
3A |
|
Peak |
30A |
|
Cross Reg. |
±5% |
|
Line Reg.
|
±1% |
|
Ripple & Noise |
50mVp-p |
V2
+3.3V
|
Max. Load |
14A |
|
Min. Load |
0A |
|
Peak |
21A |
|
Cross Reg. |
±5% |
|
Line Reg.
|
±1% |
|
Ripple & Noise |
33mVp-p |
V3
+12V
|
Max. Load |
10A |
|
Min. Load |
1A |
|
Peak |
12A |
|
Cross Reg. |
±5% |
|
Line Reg.
|
±1% |
|
Ripple & Noise |
100mVp-p |
V4
-5V
|
Max. Load |
1A |
|
Min. Load |
0A |
|
Peak |
|
|
Cross Reg. |
±2% |
|
Line Reg.
|
±1% |
|
Ripple & Noise |
50mVp-p |
V5
-12V
|
Max. Load |
2A |
|
Min. Load |
0A |
|
Peak |
3A |
|
Cross Reg. |
±10% |
|
Line Reg.
|
±1% |
|
Ripple & Noise |
100mVp-p |
V6
+5V SB
|
Max. Load |
1A |
|
Min. Load |
0A |
|
Peak |
2A |
|
Cross Reg. |
±5% |
|
Line Reg.
|
±1% |
|
Ripple & Noise |
50mVp-p |
Form Factor
PS/2
Ordering Information
VTC0144 - 12V DC input industrial power supply, ATX
|