Output
Voltage/
Current Options |
| 2.2V/30A |
| 3.3V/25A |
| 5V/20A |
| 12V/9A |
| 15V/8A |
| 24V/3A |
|
| Output
Power |
500
Watts max at 105-264 Vac
400 Watts max at 85-264 Vac |
| Input
Voltage/Current |
85-264
Vac, 47-63 Hz, 10 A max, single phase |
| Inrush
Current |
40A max |
| Efficiency |
75% min |
| Holdup
Time |
20 msec
min from input power failure until AC OK signal drops |
| AC
Fail Warning |
5 msec
min continued operation after AC OK signal drops |
| Auziliary
Output |
+5 Vdc,
100 mA |
| Voltage
Adjust |
+10%
each output independently with trimpot or program voltage |
| Paralleling |
Any
number of modules of the same voltage and polarity can be
paralleled and will share current to within 10% |
| Remote
Sense |
Compensates
for up to 0.5V total distribution voltage drop. Not required
for operation |
| Line/Load
Regulation |
0.5%
typical over AC input range and 0-100% load, measured at
output terminals |
| Ripple/Noise |
50 mV
max for outputs of 5V and below.
1% max for outputs above 5V. Peak-to-peak, dc to 10 MHz |
| Over-Voltage |
Shutdown
at 130% of nominal Vout. Recycle power to reset |
| Dynamic
Response |
3%
typical deviation with 200 usec recovery for 25-75% load step
0.1A/usec slew rate on any output |
| Overshoot/Undershoot |
None at
turn-on or turn-off |
| Temperature
Coefficient |
.02% of
Vo per ° C max |
| Turn-on
Time |
800
msec max from AC power up. 300 msec max from ON/STANDBY
switch. 20 msec max from module INHIBIT signal |
| Over-Temperature |
Shutdown
at internal heat exchanger temperature of 90° C. Recycle
power or global inhibit to reset |
| Current
Limiting |
Straight-line
current limiting at 110% of max output current for each
plug-in module.
Automatic reset |
| Input
Fuse |
Internal
one-pole 10A NTD fuse |
| Output
Isolation |
All
control signals and outputs are floating SELV circuits with
reinforced insulation to the AC primary circuits. The returns
can be grounded to system earth ground or floated to 100 V
above earth ground. Consult factory for series connection of
outputs |
| Leakage
Current |
1.5 mA
max at 240 Vac |
| Dielectric
Strength |
2200
Vdc |
| Indicators |
Externally
visible green LEDs indicating AC OK and DC OK |
| N
+ 1 Redundant |
Consult
factory for optional OR-ing diodes and N+1 redundant operation |
| Mating
Connectors |
12 pin
AMP part no. 87631-7
6 pin AMP part no. 102241-1 |
| Cooling |
Self-contained
ball-bearing dc fan |
| Operating
Temperature |
-20° C
to 70° C. Full power to 50° C, derate power to 50% at 70° C |
| Storage
Temperature |
-40° C
to 85° C |
| Humidity |
95%
non-condensing |
| Shock/Vibration |
Ruggedized
construction |
| Size/Weight |
2.7"H
x 5.8"W x 7.5"L, 3.7 lbs |