| Output
Voltage / Current Options |
| 2.2V/30A |
2.2V/60A |
2.2V/75A |
| 3.3V/25A |
3.3V/50A |
3.3V/70A |
| 5V/20A |
5V/40A |
5V/60A |
| 12V/9A |
12V/18A |
n/a |
| 15V/8A |
15V16A |
n/a |
| 24V/3A |
24V/10A |
n/a |
| n/a |
28V/10A |
n/a |
|
| Output
Power |
2000
Watts max at 170-264 Vac
1200 Watts max at 105-264 Vac
1000 Watts max at 95-264 Vac
900 Watts max at 85-264 Vac |
| Input
Voltage/Current |
85-264
Vac, 47-63 Hz, 15 A max, single phase |
| Power
Factor |
0.99
typical |
| Inrush
Current |
40
A max |
| Efficiency |
75%
typical |
| Holdup
Time |
20
msec min from input power failure until FAIL#
signal drops, at full load and 85-264 Vac. 50 ms min
for sub 1000 Watt operation |
| AC
Fail Warning |
5
msec min continued operation after AC OK signal
drops |
| Auxiliary
Output |
+5
Vdc, 100 mA |
| Voltage
Adjust |
+10%
each outopout independently with trimpot or program
voltage input (except for 28V which is +2%/-%30) |
| Paralleling |
Any
number of modules of the same voltage and polarity
can be paralleled and will share current to within
10% |
| Remote
Sense |
Compensates
for up to 0.5V total distribution voltage drop. Not
required for operation |
| Line/Load
Regulation |
0.5%
typical over AC input range and 0-100% load,
measured at output terminals |
| Minimum
Load |
None
required |
| Ripple/Noise |
50mV
max for outputs of 5V and below. 1% max for outputs
above 5V. Peak-to-Peak, dc to 10MHz |
| Over-Voltage |
Shutdown
at 130% of nominal Vout. Recycle power to reset |
| Dynamic
Response |
3%
typical deviation with 200 usec recovery for 25-75%
load step 0.1A/usec slew rate on any output |
| Overshoot/Undershoot |
None
at turn-on or turn-off |
| Temperature
Coefficient |
.02%
of Vo per ° C max |
| Turn-on
Time |
800
msec max from AC power up. 300 msec max from
ON/STANDBY switch. 20 msec max from module INHIBIT
signal |
| Over-Temperature |
Shutdown
at internal heat exchanger temperature of 90C.
Recycle power or global inhibit to reset |
| Current
Limiting |
Straight-line
current limiting adjustable from 20% to 110% of max
output current for each plug-in module. Automatic
reset |
| Input
Fuse |
Internal
one-pole 20A fuse |
| Output
Isolation |
All
control signals and ouputs are floating SELV
circuits with reinforced insulation to the AC
primary circuits. The returns can be grounded to
system earth ground or floated to 100 V above earth
ground. Consult factory for series connection of
outputs |
| Leakage
Current |
1.5
mA max at 240 Vac |
| Hipot |
2200
Vdc |
| Indicators |
Externally
visible green LEDs indicating AC OK and DC OK |
| N+1
Redundant |
Consult
factory for optional OR-ing diodes and N+1 redundant
operation |
| Connectors |
14
pin AMP part no. 87631-9
6 pin AMP part no.
102241-4
|
| Cooling |
Two
self-contained ball-bearing dc fans |
| Operating
Temperature |
-20°
C to 70° C.Full power to 50° C, derate power to
50% at 70° C |
| Storage
Temperature |
-40°
C to 85° C |
| Humidity |
95%
non-condensing |
| Shock/Vibration |
Ruggedized
construction |
| Size/Weight |
3.5"H
x 8"W x 12"L, 11 lbs. |
| NOTE |
Specifications
subject to change without notice |