Dimensions
150x140x86 mm / 5.9"x5.5"x3.4"
Safety Approval
TÜV, CSA, NRTL/C, UL
Temperature/Humidity
0 ~ 70°C (-20°C can start up)
The maximum output power should be under the cabinet temperature 30°C
MTBF
> 150,000 hrs
Over Load Protection
Total o/p 110% ~ 130%
Over Voltage Protection
+5V: 5.6 ~ 6.5V
Efficiency
> 65%
Input Current
20A@24V DC input
Input Voltage
DC 19V ~ 32V for 24V DC input
DC Output
+5V
Max. Load 30A
Min. Load
2A
Max.Watt
150W
Load Reg.
±3%
Cross Reg. ±5%
Line Reg.
±1%
Ripple
±1%
Noise
±1%
+3.3V
Max. Load 15A
Min. Load
0A
Max.Watt
150W
Load Reg.
±2%
Cross Reg. ±5%
Line Reg.
±1%
Ripple
±1%
Noise
±1%
+12V
Max. Load 15A
Min. Load
0.1A
Max.Watt
180W
Load Reg.
±5%
Cross Reg. ±5%
Line Reg.
±1%
Ripple
±1%
Noise
±1%
-5V
Max. Load 2A
Min. Load
0A
Max.Watt
10W
Load Reg.
±2%
Cross Reg. ±10%
Line Reg.
±1%
Ripple
±1%
Noise
±2%
-12V
Max. Load 2A
Min. Load
0A
Max.Watt
24W
Load Reg.
±2%
Cross Reg. ±10%
Line Reg.
±1%
Ripple
±1%
Noise
±2%
Other Features
-48 or +24 V DC input, ATX output
Provide 1.2A for stand-by +5V
Provide +5V o/p to have OVP design
-20°C can start up
Form Factor
PS/2
Ordering Information
VTC0110-300W PS/2 type 24V DC/DC converter with ATX output
|