Intel® Dual Pentium® III w/ 100/133MHz FSB up to
1GHz |
 |
Intel® 440BX or VIA Apollo PRO 266 Chipsets |
 |
C&T 69000 VGA |
 |
Dual Intel® 82559 Ethernet |
 |
3.5" HDD bay x 2; 3.5" slim FDD bay x 1,
5.25" slim CD-ROM bay x 1; IDE RAID 0,1 (U160 SCSI SCA-2
RAID 0,1 for NEXSERVER 1210) |
 |
32 bit/33MHz PCI expansion slot x 1 |
 |
250W Power Supply |
|
|
|

Construction
- 1U height 19" rackmount chassis
Disk drive and bays
- slim CD-ROM x1, slim floppy x 1, 3.5" Hot-swap bays x 2
Dimension (W x H x D)
- 482.6 x 44 x 600 (mm)
19 x 1.75 x 23.6 (inch)
Weight
RAID backplane module
- Support Ultra160 SCSI RAID System
- 1.0" HDD 2 units
- Each HDD is connected by SCA-2 Connector
- Rush current protection
- SCSI Terminator on this backplane
- Temperature Fail Detect and alarm
- Fan Fail detect and Alarm
- IDE RAID
- Host interface Ultra DMA 33/66
- Disk interface Ultra DMA 33/66
- Automatic On-line rebuilding
- Host transparent and OS independent
- Hot-swap for drives
- Battery backup for disk array status
- Audible alarm on drive failure
System Cooling
- One 10 cm and one 4cm FAN
Front panel indicator
- Power ON LED (Green), Power Fail LED (Red), LAN LED x 2 (Green),
Temperature failure warming LED (Red), Fan failure warning LED
(Red), HDD status LED(Green) HDD access LED (Yellow)
Front panel switches
- Reset switch, Power ON/OFF switch, Buzzer off switch
RISER card
System operating temperature
Relative humidity
- 20-90% non-condensing at 86°F (30°C).
NEXSERVER 1200 series Options
| ATX Main Board Models |
6320VL2 / 6320A |
| Intel® Dual Processor supported |
Pentium® III up to 1 GHz+ |
| Intel® Chipset |
440BX chipset |
| Memory support (Max.) |
1GB SDRAM |
| Bays |
slim CD-ROM x1, slim floppy x 1, 3.5" Hot-swap bays x 2 |
| Network |
Dual Intel® 82559 Ethernet |
| SCSI Controller |
Dual Channel Ultra 160 SCSI for 6320A ONLY |
| VGA Controller |
C&T 69000/69030 |
| Power Supply |
250W SPS |
| Operating Systems Supported |
Windows® 95/98/2000, NT4.0, SCO Open Server 5.0, Solaris 8.x,
Redhat Linux 6.x |
Server Management Software -- NEXCARE
- Detect client site CPU temperature, and the Vcore voltage levels.
- Monitor client site error message by console site
Power supply
| Specifications |
| Watt |
Input |
Maxi-load |
Mini-load |
| 250W |
115/230V~10A/5A, 60/50Hz |
+5V @30A
+3.3V @15A
+12V @12A
-5V @0.5A
-12V @0.6A
+5Vsb @1.5A |
+5V @3A
+3.3V @1A
+12V @1A |
UL, CSA, TUV, CE approved

NEXSERVER 1200-6320VL2
-
- Chassis with 250W ATX single power supply,
IDE-IDE RAID module and Dual processor MB NEX 6320VL2
NEXSERVER 1210-6320VL2
-
- Chassis with 250W ATX power supply, Ultra
160 SCSI backplane (w/o RAID function), and Dual processor
MB NEX 6320VL2
NEXSERVER 1210-6320A
-
- Chassis with 250W ATX power supply,
External SCSI RAID card level 0 &1, and Dual processor
MB NEX 6320A
Options
-
- SCSI RAID Card level 0,1
|
|
|