![]() View Larger Image |
| General | |
| General Specifications (PS) | Input Range: 100 to 240 VAC, +/-10% Power Factor: 0.95 minimum Efficiency: 70% minimum, at full load Hold up Time: 20mS minimum, at full load PSON (Remote ON/OFF): TTL compatible signal Power Good: 100 to 500 ms, TTL compatible signal Cooling Fan: 40x40x20 mm Operating Temperature: 0 to 50 degree Operating Humidity: 20 to 90 % |
| Agency Requirements & Regulations | |
| Agency Requirements | Harmonic: Meet EN61000-3-2 standards EMI/RFI: CE, FCC class B and CISPR class B Safety: UL, cUL, CB, TUV |
| Input (PS) | |
| Input (PS) | Input Voltage: 100-240VAC Input Frequency: 47-63Hz Input Current: 5-2.5A |
| Notes | |
| Notes (PS) | 1. The +5, +3.3 and +12 Volt combine total output shall not exceed 230W for EFA-250 and 280W for EFA-300. 2. Noise bandwidth is from DC to 20 MHz. |
| Output Total Power | |
| Total Output Power Operating Max | 300 W |
| Output Voltage | |
| +12V1 VDC | Max Load Current: 15A Min Load Current: 1A Load Regulation: ±5% Cross Regulation: ±5% Line Regulation: ±1% Ripple & Noise: 120mV |
| +3.3 VDC | Max Load Current: 30A Min Load Current: 3A Load Regulation: ±5% Cross Regulation: ±5% Line Regulation: ±1% Ripple & Noise: 50mV |
| +5 VDC | Max Load Current: 30A Min Load Current: 0A Load Regulation: ±5% Cross Regulation: ±5% Line Regulation: ±1% Ripple & Noise: 50mV |
| +5 Vsb DC | Max Load Current: 2A Min Load Current: 0A Load Regulation: ±5% Cross Regulation: ±5% Line Regulation: ±1% Ripple & Noise: 50mV |
| -12 VDC | Max Load Current: 0.8A Min Load Current: 0A Load Regulation: ±10% Cross Regulation: ±10% Line Regulation: ±1% Ripple & Noise: 120mV |
Features: