Source for VMEbus, PMC Modules, CompactPCI, Single Board Computers, Rackmount Servers, and Rackmount Chassis

Ordering Form   

Unit of Measurement Converter

 

DataSplit™ Online DataSheet

Connect Routers, 56 Kbps Equipment, PBXs and More into a Single T1 Communications Link.

The expandable, affordable T1 solution for splitting off high-speed data. The DataSplit T1 CSU/DSU Multiplexer from VoxTechnologies Corp., combines an intelligent T1 Channel Service Unit and Data Service Unit with T1 multiplexing functions providing voice and data integration over a T1 line. The DataSplit 'splits' off high-speed data channels from a T1 line with the option of passing on the remaining T1 channels to other voice or data equipment. Each data channel can then be programmed for any Fractional T1 data rate, in increments of 56Kbps or 64Kbps, up to the full 1.536 Mbps available. The DataSplit delivers V.35 or RS-449 interfaces to connect computer ports, LAN routers/hubs, terminal servers, statistical Multiplexers, subrate voice/data compressors and video teleconferencing equipment.

Flexible. Expandable. 'Future-Proof'.

The DataSplit easily accommodates growing communications requirements. Its modular design incorporates removable Drop and Insert and Dual Data Port interfaces. This enables a DataSplit originally equipped with just a single T1 Network Port to add a Drop and Insert port simply by plugging in a new card. Data ports can also be expanded from two to four high-speed V.35 or RS-449 interfaces by adding a field-replaceable card.

If more than four data ports are required, multiple DataSplit units can be cascaded using the T1 Drop and Insert port. Units can be separated up to 1,200 feet for high-speed data distribution - using existing twisted pair wiring in a campus or multi-story environment.

Easy Configuration and System Status

The DataSplit exemplifies CAC's reputation for providing T1 access solutions that offer simplified configuration and operation. The LCD display and menu keys provide on-site diagnostics and configurations. Multi-colored LEDs enable the user to quickly perform visual checks of T1 and data port conditions.

Terminal Management and Optional SNMP

The DataSplit offers standard VT-100 terminal management capabilities on the supervisory port. This feature provides terminal or modem access for system configuration, testing, and performance monitoring. A remote DataSplit can be managed from one end of the T1 line when using the Extended Super Frame (ESF) T1 facility data link.

As an option, the DataSplit CSU/DSU T1 Multiplexer also provides Simple Management Network Protocol (SNMP). An Async Supervisory Port provides the embedded SNMP agent functionality, using the SLIP protocol.

The Perfect Solution for Cellular, PCS, and Battery-Backed Applications

Easy expansion, simplified management, and proven reliability. These are just some of the important advantages you'll discover with the DataSplit T1 DSU/CSU Multiplexer from High-Speed Networks Inc. It offers user-friendly interfaces and advanced service features such as field-replaceable T1 and data interface cards. And DataSplit offers both A.C. and -48 Vdc right out of the box, enabling you to simply 'plug and go' to meet your next T1 data communications challenge. DataSplit. From Carrier Access, the T1 value leader.

DataSplit Specifications

Model Numbers  
2 2 high-speed user Data Ports, T1 CSU Network Port
2I 2 high-speed user Data Ports, T1 CSU Network Port, T1 Drop and Insert Port (used for PBX connections or cascading Data Splits)
4 4 high-speed user Data Ports, T1 CSU Network Port
4I 4 high-speed user Data Ports, T1 CSU Network Port, T1 Drop and Insert Port
T1 Network Interface (Models 2I & 4I only)  
Line Rate 1.544 Mbps +/- 50 bps
Framing SF or ESF (software selectable)
Line Code AMI or B8ZS (software selectable)
Input Signal DSX-1 from 0dB to -30dB
Output Signal DSX-1 with LBO of 0, 7.5, or 15 dB (software selectable)
Mechanical DB15P (male)
Configuration Stored in non-volatile memory
Data Port Interfaces  
Number of Ports 2 or 4 (field up-gradable)
Bit Rate Synchronous Nx56 Kbps or Nx64 Kbps (N = 1...24)
Electrical V.35 or RS-449 (software selectable)
Mechanical DB25S (conversion cables available for other standard connectors
Clocking Normal or Inverted
Data Normal or Inverted (supports clear-channel HDLC)
Idle Pattern Any 8-bit pattern selectable
Configuration Stored in non-volatile memory
Clocking Options  
Clock Sources Internal, Network Port, Drop and Insert Port, DTE Ports, External Coax connection at Nx56 Kbps, Nx64 Kbps, 1.544 Mbps, or 6.176 Mbps
Configuration Stored in non-volatile memory
Network Management Port  
Electrical RS-232 DTE on Db9P connector
Interface Device Serial ASCII VT 100-compatible terminal or emulation software. SNMP Proxy Agent Software optional.
Data Speeds 300, 1200, 2400, 4800, 9600 asynchronous
Performance Monitoring  
Monitors T1 Network, T1 Drop and Insert, and DTE Ports
Registers Separate Registers for Carrier and User
Reports Current port status is displayed for both the near-end and far-end units (requires use of ESF FDL for far-end reports). One-hour and 24-hour reports include time, date, and several error counts. Individual reports show the last 96 of 15 minute intervals. 24-hour line availability is calculated. Continuous alarm history records and counts (by alarm type) are stored.
Error Counts Bipolar Violations, ESF CRCs, Errored Seconds, Bursty Seconds, Severely Errored Seconds, Unavailable Seconds, Slip Seconds, Loss of Frame Count.
Alarms  
LEDs Power, Remote Loop Back, Line, Drop & Insert, ACO, DTE1, DTE2, DTE3, DTE4 (red, green, yellow, and flashing to indicate current status of port)
Contacts Normally Open, Common, Normally Closed Contacts for software-selectable System alarms. Separate contacts for power fuse alarm.
Activation For both the T1 Network Port and the T1 Drop and Insert Port, the following alarm types can be selected for activation: Loss of Signal, Yellow Alarm, Alarm Indication Signal Received, Loss of Frame, Bipolar Violation Threshold Exceeded, Errored Seconds Threshold Exceeded, Unavailable Seconds Threshold Exceeded. An additional alarm type for the T1 Network Port is Slip Indication. A system-level Master Clock Loss alarm is also selectable. All 4 of the high-speed user data ports may be selected to alarm when the RTS signal from the attached DTE is lost, or when the incoming Data Clock is lost.
ACO (Alarm Cut-Off) Front Panel or Network Management Port
Alarm Message Electrical Interface: RS-232 Network Management Port Auto Alarm Dial Out: Standard AT Modem Command Set, 32 characters Telephone Numbers: Primary and Secondary Message Contents: Origination Nome, Alarm Type, Set/Clear, Time, Date
Loop Backs and Diagnostics  
T1 Loop Backs Remote T1 Network loop backs sent as In-Band, AT&T ESF, or ANSI ESF. Remote T1 Drop and Insert loop backs sent in-band on the Drop and Insert time slots only. Local loop backs can be set in either direction for the T1 Network Port or T1 Drop and Insert Port.
Data Port Loop Backs Remote Data Ports can be individually looped by sending an in-band code to the far-end. Codes are sent only on the fractional portion of the T1 under-test - without affecting other channels.
BERT Codes QRSS, 3-in-24 , 1-in-8, 2-in-8, and 1-to-1 patterns can be sent on the entire T1, or the fractional portion dedicated to an individual Data Port or the Drop and Insert Port without affecting other channels. Bit Error Counts, Errored Seconds, and Elapsed Seconds Are Displayed.
Activation Front panel or Network Management Port
Power  
  -36 to -72 Vdc (-48 Vdc nominal) @ 450 mA or less A 115 Vac to -48 Vdc wall-plug power adapter is provided with each DataSplit. Input dc power floats with respect to chassis and data grounds - providing data integrity in separated equipment installations.
Physical  
Dimensions Desk Top, 19" Rack-Mount, or Wall-Mount (brackets provided) 16.9"W x 1.7"H x 12.2"L
Weight 6 lbs. nominal
Environmental  
Operating Temperature 0 to 50 C ambient
Relative Humidity 0% to 95% RH, 10 to 38 C, non-condensing
Compliance and Compatibility  
AT&T TR54016 - ESF Data Link Message Support
AT&T TR 62411
ANSI T1.403 - ESF Facility Data Link Performance Report Message (PRM)
FCC Compliance Part 68, Reg. #2Z6TAI-75962-DE-N, Part 15, Class A
NRTL Listed UL 1459, 2nd Edition
CSA C22.2, 225
DOC CS-03 (pending)

Specifications subject to change without notice.


VoxTechnologies - Industrial Computer Leader Back to Home E-Mail   VoxTechnologies Corp. - Industrial Computer Leader
Tel:
972-234-4343 Fax: 972-234-4295 Toll-Free: 1-888-568-6224
 

An Industrial Partner 1999-2002. All rights reserved.


CompactPCI, Embedded SBCs, Flat panel Displays, Industrial Chassis, IndustrialPC Peripherals, Industrial Power Supplies, Backplanes, Single Board Computers, Rackmount Servers, Network Communication, Open Frame Panel Computer, PC/104, Flash Disk, CTI, RAID Back to Home CompactPCI, Embedded SBCs, Flat panel Displays, Industrial Chassis, IndustrialPC Peripherals, Industrial Power Supplies, Backplanes, Single Board Computers, Rackmount Servers, Network Communication, Open Frame Panel Computer, PC/104, Flash Disk, CTI, RAID E-Mail

VoxTechnologies Corp. - Industrial Computer Leader
Tel:
1-972-234-4343 Fax: 1-972-234-4295 Toll-Free: 1-888-568-6224

For over a decade, VoxTechnologies has been a leading source of industrial computers and complete system products for the O.E.M. and Systems Integrator. Our primary goal is to provide a solution source for engineers that have the challenging task of interfacing and controlling the real world.

Telephone: 1-972-234-4343 General Info: info@voxtechnologies.com Sales Info: sales@voxtechnologies.com
 
We accept all major credit cardsRelated Links Adtran AFC CAC Larscom Metrobility Moxa NetAnchor
VTC SBCs, VTC Chassis, VTC Backplanes, VTC CompactPCI, VTC Power Supplies, VTC Peripherals, Other SBCs, Other Backplanes, Other Chassis, Other Power Supplies, Other Embedded SBCs, Other CompactPCI Devices, Other Servers, Other Network Storage, Other VME, RAD,
CAC, Charles, Eastern, Transition, Other PC/104 Products, Other Subsystems, Other KVM Switches, Other Flat Panels, Other Plasma Engine Computers, Other ACTI Platforms, Other Industrial Peripherals, Other Network Communication Products, IPCMall, PLCPartner, Moxa, Telco, Etasis, Axiom, IEI, Channel Banks, Adtran, PowerSupplyPartner, DelvingWare
Archives
Send mail to webmaster@voxtechnologies.com with questions or comments about this web site.
Copyright © 1999 VoxTechnologies Corporation- An Industrial Partner
Last modified: November 30, 2002   Proud Sponsor of Dallas Jazz