DataSplit Online DataSheet
Connect Routers, 56 Kbps Equipment, PBXs and More into a Single T1 Communications
Link.
The expandable, affordable T1 solution for splitting off high-speed data. The DataSplit
T1 CSU/DSU Multiplexer from VoxTechnologies Corp., combines an intelligent T1 Channel
Service Unit and Data Service Unit with T1 multiplexing functions providing voice and data
integration over a T1 line. The DataSplit 'splits' off high-speed data channels from a T1
line with the option of passing on the remaining T1 channels to other voice or data
equipment. Each data channel can then be programmed for any Fractional T1 data rate, in
increments of 56Kbps or 64Kbps, up to the full 1.536 Mbps available. The DataSplit
delivers V.35 or RS-449 interfaces to connect computer ports, LAN routers/hubs, terminal
servers, statistical Multiplexers, subrate voice/data compressors and video
teleconferencing equipment.
Flexible. Expandable. 'Future-Proof'.
The DataSplit easily accommodates growing communications requirements. Its modular
design incorporates removable Drop and Insert and Dual Data Port interfaces. This enables
a DataSplit originally equipped with just a single T1 Network Port to add a Drop and
Insert port simply by plugging in a new card. Data ports can also be expanded from two to
four high-speed V.35 or RS-449 interfaces by adding a field-replaceable card.
If more than four data ports are required, multiple DataSplit units can be cascaded
using the T1 Drop and Insert port. Units can be separated up to 1,200 feet for high-speed
data distribution - using existing twisted pair wiring in a campus or multi-story
environment.
Easy Configuration and System Status
The DataSplit exemplifies CAC's reputation for providing T1 access solutions that offer
simplified configuration and operation. The LCD display and menu keys provide on-site
diagnostics and configurations. Multi-colored LEDs enable the user to quickly perform
visual checks of T1 and data port conditions.
Terminal Management and Optional SNMP
The DataSplit offers standard VT-100 terminal management capabilities on the
supervisory port. This feature provides terminal or modem access for system configuration,
testing, and performance monitoring. A remote DataSplit can be managed from one end of the
T1 line when using the Extended Super Frame (ESF) T1 facility data link.
As an option, the DataSplit CSU/DSU T1 Multiplexer also provides Simple Management
Network Protocol (SNMP). An Async Supervisory Port provides the embedded SNMP agent
functionality, using the SLIP protocol.
The Perfect Solution for Cellular, PCS, and Battery-Backed Applications
Easy expansion, simplified management, and proven reliability. These are just some of
the important advantages you'll discover with the DataSplit T1 DSU/CSU Multiplexer from
High-Speed Networks Inc. It offers user-friendly interfaces and advanced service features
such as field-replaceable T1 and data interface cards. And DataSplit offers both A.C. and
-48 Vdc right out of the box, enabling you to simply 'plug and go' to meet your next T1
data communications challenge. DataSplit. From Carrier Access, the T1 value leader.
DataSplit Specifications
| Model Numbers |
|
| 2 |
2 high-speed user Data Ports, T1 CSU Network Port |
| 2I |
2 high-speed user Data Ports, T1 CSU Network Port, T1 Drop and Insert Port (used for
PBX connections or cascading Data Splits) |
| 4 |
4 high-speed user Data Ports, T1 CSU Network Port |
| 4I |
4 high-speed user Data Ports, T1 CSU Network Port, T1 Drop and Insert Port |
| T1 Network Interface (Models 2I & 4I only) |
|
| Line Rate |
1.544 Mbps +/- 50 bps |
| Framing |
SF or ESF (software selectable) |
| Line Code |
AMI or B8ZS (software selectable) |
| Input Signal |
DSX-1 from 0dB to -30dB |
| Output Signal |
DSX-1 with LBO of 0, 7.5, or 15 dB (software selectable) |
| Mechanical |
DB15P (male) |
| Configuration |
Stored in non-volatile memory |
| Data Port Interfaces |
|
| Number of Ports |
2 or 4 (field up-gradable) |
| Bit Rate |
Synchronous Nx56 Kbps or Nx64 Kbps (N = 1...24) |
| Electrical |
V.35 or RS-449 (software selectable) |
| Mechanical |
DB25S (conversion cables available for other standard connectors |
| Clocking |
Normal or Inverted |
| Data |
Normal or Inverted (supports clear-channel HDLC) |
| Idle Pattern |
Any 8-bit pattern selectable |
| Configuration |
Stored in non-volatile memory |
| Clocking Options |
|
| Clock Sources |
Internal, Network Port, Drop and Insert Port, DTE Ports, External Coax connection at
Nx56 Kbps, Nx64 Kbps, 1.544 Mbps, or 6.176 Mbps |
| Configuration |
Stored in non-volatile memory |
| Network Management Port |
|
| Electrical |
RS-232 DTE on Db9P connector |
| Interface Device |
Serial ASCII VT 100-compatible terminal or emulation software. SNMP Proxy Agent
Software optional. |
| Data Speeds |
300, 1200, 2400, 4800, 9600 asynchronous |
| Performance Monitoring |
|
| Monitors |
T1 Network, T1 Drop and Insert, and DTE Ports |
| Registers |
Separate Registers for Carrier and User |
| Reports |
Current port status is displayed for both the near-end and far-end units (requires use
of ESF FDL for far-end reports). One-hour and 24-hour reports include time, date, and
several error counts. Individual reports show the last 96 of 15 minute intervals. 24-hour
line availability is calculated. Continuous alarm history records and counts (by alarm
type) are stored. |
| Error Counts |
Bipolar Violations, ESF CRCs, Errored Seconds, Bursty Seconds, Severely Errored
Seconds, Unavailable Seconds, Slip Seconds, Loss of Frame Count. |
| Alarms |
|
| LEDs |
Power, Remote Loop Back, Line, Drop & Insert, ACO, DTE1, DTE2, DTE3, DTE4 (red,
green, yellow, and flashing to indicate current status of port) |
| Contacts |
Normally Open, Common, Normally Closed Contacts for software-selectable System alarms.
Separate contacts for power fuse alarm. |
| Activation |
For both the T1 Network Port and the T1 Drop and Insert Port, the following alarm
types can be selected for activation: Loss of Signal, Yellow Alarm, Alarm Indication
Signal Received, Loss of Frame, Bipolar Violation Threshold Exceeded, Errored Seconds
Threshold Exceeded, Unavailable Seconds Threshold Exceeded. An additional alarm type for
the T1 Network Port is Slip Indication. A system-level Master Clock Loss alarm is also
selectable. All 4 of the high-speed user data ports may be selected to alarm when the RTS
signal from the attached DTE is lost, or when the incoming Data Clock is lost. |
| ACO (Alarm Cut-Off) |
Front Panel or Network Management Port |
| Alarm Message |
Electrical Interface: RS-232 Network Management Port Auto Alarm Dial Out: Standard AT
Modem Command Set, 32 characters Telephone Numbers: Primary and Secondary Message
Contents: Origination Nome, Alarm Type, Set/Clear, Time, Date |
| Loop Backs and Diagnostics |
|
| T1 Loop Backs |
Remote T1 Network loop backs sent as In-Band, AT&T ESF, or ANSI ESF. Remote T1
Drop and Insert loop backs sent in-band on the Drop and Insert time slots only. Local loop
backs can be set in either direction for the T1 Network Port or T1 Drop and Insert Port. |
| Data Port Loop Backs |
Remote Data Ports can be individually looped by sending an in-band code to the
far-end. Codes are sent only on the fractional portion of the T1 under-test - without
affecting other channels. |
| BERT Codes |
QRSS, 3-in-24 , 1-in-8, 2-in-8, and 1-to-1 patterns can be sent on the entire T1, or
the fractional portion dedicated to an individual Data Port or the Drop and Insert Port
without affecting other channels. Bit Error Counts, Errored Seconds, and Elapsed Seconds
Are Displayed. |
| Activation |
Front panel or Network Management Port |
| Power |
|
| |
-36 to -72 Vdc (-48 Vdc nominal) @ 450 mA or less A 115 Vac to -48 Vdc wall-plug power
adapter is provided with each DataSplit. Input dc power floats with respect to chassis and
data grounds - providing data integrity in separated equipment installations. |
| Physical |
|
| Dimensions |
Desk Top, 19" Rack-Mount, or Wall-Mount (brackets provided) 16.9"W x
1.7"H x 12.2"L |
| Weight |
6 lbs. nominal |
| Environmental |
|
| Operating Temperature |
0 to 50 C ambient |
| Relative Humidity |
0% to 95% RH, 10 to 38 C, non-condensing |
| Compliance and Compatibility |
|
| AT&T |
TR54016 - ESF Data Link Message Support |
| AT&T |
TR 62411 |
| ANSI |
T1.403 - ESF Facility Data Link Performance Report Message (PRM) |
| FCC Compliance |
Part 68, Reg. #2Z6TAI-75962-DE-N, Part 15, Class A |
| NRTL Listed |
UL 1459, 2nd Edition |
| CSA |
C22.2, 225 |
| DOC |
CS-03 (pending) |
Specifications subject to change without notice.
 |
Back
to Home |
E-Mail
|
VoxTechnologies Corp. - Industrial
Computer Leader
Tel: 972-234-4343 Fax: 972-234-4295 Toll-Free:
1-888-568-6224 |
|