Source for VMEbus, PMC Modules, CompactPCI, Single Board Computers, Rackmount Servers, and Rackmount Chassis

Ordering Form   

Unit of Measurement Converter

 

VoxTechnologies Enterprise Networks

DSU III DBU

DEDICATED RACKMOUNT DSU/CSU WITH SWITCHED DIAL BACKUP

The ADTRAN DSU III DBU RM, a high-performance rackmount data channel service unit (DSU/CSU), provides an interface between the digital data service (DDS) and the customers data terminal equipment (DTE) while providing automatic switched dial backup (DBU) of the dedicated circuit. There are four DBU options: 4-wire Switched 56 (SW56), 2-wire SW56, V.34, and 1B+D ISDN. When the DSU III DBU is configured for dedicated service with switched DBU, the user selects options to qualify a dedicated line failure. Upon line failure recognition, the DSU initiates connection to the remote unit over the switched network. Upon restoral of the DDS circuit, the unit automatically or manually reverts to the restored DDS circuit.

The DSU III DBU supports synchronous operations at rates of 2.4, 4.8, 9.6, 19.2, 38.4, 56 and 64 kbps and asynchronous data rates of 2.4, 4.8, 9.6, 19.2, 38.4, and 57.6 kbps. The DTE interface can be selected as either EIA-232 or V.35 for all data rates. Another feature is DTE-to-service rate matching, for dedicated and switched DBU modes. This feature allows slower rate DTE equipment to communicate over a higher speed digital line. In the DBU mode, dialing is accomplished automatically (with stored numbers) or manually.

The DSU III DBU can be configured through the Smart 16/16e shelf controller card from a local/remote VT 100 terminal or from an ADTRAN DATAMATETM. The DSU III DBU can also be configured using AT or V.25 bis commands.

The unit responds to standard loopback commands from the telephone company central office. The front panel LEDs display test status, alarms, and errors during a test and DBU status. Automatic service rate detection and pair reversal detection aid installation.

Features

  • Automatic conversion to switched mode upon failure of dedicated service
  • Four backup options available: 4-wire SW56, 2-wire SW56, V.34, and 1B+D ISDN
  • Synchronous or asynchronous (including 57.6 kbps) modes of operation
  • EIA-232 and V.35 DTE interfaces
  • DTE-to-service rate matching feature allows slower DTE devices to communicate over higher rate service offerings
  • Tail circuit operation support with internal slack data buffer
  • Manual and automatic dialing capability
  • Auto answer of incoming calls
  • Standard 5-year warranty

DSU III DBU APPLICATION EXAMPLE


Product Specifications

OPERATING MODES

  • Dedicated DDS
  • Dedicated DDS with automatic switched DBU

SWITCHED DIAL BACKUP

  • Automatic or manual
  • 4-wire SW56
  • 2-wire SW56
  • V.34
  • ISDN (1B+D)

NETWORK DATA RATES

  • Dedicated mode service rates: 2.4, 4.8, 9.6, 19.2, 38.4, 56 and 64 kbps
  • Dial backup: Switched 56 (56 kbps), V.34 (2.4/33.6 kbps), ISDN (56/64 kbps)

DTE RATES

  • DTE-to-loop rate matching in both dedicated and switched backup modes
  • Synchronous rates: 2.4, 4.8, 9.6, 19.2, 38.4, and 56 kbps
  • Asynchronous rates: 2.4, 4.8, 9.6, 19.2, and 57.6 kbps

DTE INTERFACE

  • Both EIA-232 and V.35 electrical and physical DTE interfaces

LINE REQUIREMENTS

Loop transmission parameters as defined in:

  • AT&T PUB 62310: Dedicated DDS
  • AT&T PUB 41468: SW56

Receiver sensitivity:

  • 45dB @ all rates

Line interface:

  • RJ-48S, 4-wire, full duplex

DIAGNOSTICS

Network

  • CSU and DSU loopbacks

User

  • Local DTE and loop, remote V.54

Test patterns

  • 2047, 511, DDS stress patterns 1-4

ENVIRONMENT

Operating Temperature

  • 0° to 50°C, (32° to 122°F)

Storage Temperature

  • 20° to 70°C, (4° to 158°F)

Relative Humidity

  • Up to 95%, non-condensing

PHYSICAL

Dimensions

  • 1." H, 6.75" W, 10.5" D

Weight

  • 1.5 lbs

Power

  • 8 watts
Product Includes: Two 8-pin to 8-pin modular cables and user manual
 
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

Ordering Information

Download this brochure in pdf format.
Request more information.

csu, dsu, dacs, bandwidth manager, frame relay, remote access, pri, channel bank, bri, adtran, enterprise, fxs, fxo, t1, e1, tsu, isdn, pbx, atm, clec, plesiochronous, point-to-point, fractional, voice, data, e&m, analog, router, pstn, v.35, dsx, fsx, dbu, ethernet, network management, osu, multiport, multi-mode fiber, snmp, t3su, dacsing, ds0, ds1, ds3, drop/insert, hssi, u-interface, hdsl, imux, mux, multiplexers, cross-connect, bonding, dte, hdlc, pots, chassis, psu, rcu, eia232, ground start, foreign exchange, dpo, plar, rackmount, wallmount, tdu, ft1, t1/ft1, did, 2-wire, rj-11, spanning tree, bridging, 4-wire, eia-530, rst-232, fiber, t3, esu, dial back, sdlc, ip routing, sna/sdlc, bisync, slip,async, tbop, safe-t-net, dce, h0, h11, in-band, facilities data link, fdl, pro, sdlc-llc2, ppp, v.34, sw56, xdsl, 10baseT, vt100, ccitt/v120, ip/ipx, mlppp, remote loopback, local loopback, multilinks, aggregating, aggregate, dtr assertion, rs-366, y cable, spid, lzs compression, v.120, video conferencing, termination units, redundant power supply, g.shdsl, sonet networks, mlt, ringdown, pcm, tr-08 Back to Home csu, dsu, dacs, bandwidth manager, frame relay, remote access, pri, channel bank, bri, adtran, enterprise, fxs, fxo, t1, e1, tsu, isdn, pbx, atm, clec, plesiochronous, point-to-point, fractional, voice, data, e&m, analog, router, pstn, v.35, dsx, fsx, dbu, ethernet, network management, osu, multiport, multi-mode fiber, snmp, t3su, dacsing, ds0, ds1, ds3, drop/insert, hssi, u-interface, hdsl, imux, mux, multiplexers, cross-connect, bonding, dte, hdlc, pots, chassis, psu, rcu, eia232, ground start, foreign exchange, dpo, plar, rackmount, wallmount, tdu, ft1, t1/ft1, did, 2-wire, rj-11, spanning tree, bridging, 4-wire, eia-530, rst-232, fiber, t3, esu, dial back, sdlc, ip routing, sna/sdlc, bisync, slip,async, tbop, safe-t-net, dce, h0, h11, in-band, facilities data link, fdl, pro, sdlc-llc2, ppp, v.34, sw56, xdsl, 10baseT, vt100, ccitt/v120, ip/ipx, mlppp, remote loopback, local loopback, multilinks, aggregating, aggregate, dtr assertion, rs-366, y cable, spid, lzs compression, v.120, video conferencing, termination units, redundant power supply, g.shdsl, sonet networks, mlt, ringdown, pcm, tr-08E-Mail   VoxTechnologies Corp. - Industrial Computer Leader
Tel:
972-234-4343 Fax: 972-234-4295 Toll-Free: 1-888-568-6224
 

An Industrial Partner 1999-2002. All rights reserved.


CompactPCI, Embedded SBCs, Flat panel Displays, Industrial Chassis, IndustrialPC Peripherals, Industrial Power Supplies, Backplanes, Single Board Computers, Rackmount Servers, Network Communication, Open Frame Panel Computer, PC/104, Flash Disk, CTI, RAID Back to Home CompactPCI, Embedded SBCs, Flat panel Displays, Industrial Chassis, IndustrialPC Peripherals, Industrial Power Supplies, Backplanes, Single Board Computers, Rackmount Servers, Network Communication, Open Frame Panel Computer, PC/104, Flash Disk, CTI, RAID E-Mail

VoxTechnologies Corp. - Industrial Computer Leader
Tel:
1-972-234-4343 Fax: 1-972-234-4295 Toll-Free: 1-888-568-6224

For over a decade, VoxTechnologies has been a leading source of industrial computers and complete system products for the O.E.M. and Systems Integrator. Our primary goal is to provide a solution source for engineers that have the challenging task of interfacing and controlling the real world.

Telephone: 1-972-234-4343 General Info: info@voxtechnologies.com Sales Info: sales@voxtechnologies.com
 
We accept all major credit cardsRelated Links Adtran AFC CAC Larscom Metrobility Moxa NetAnchor
VTC SBCs, VTC Chassis, VTC Backplanes, VTC CompactPCI, VTC Power Supplies, VTC Peripherals, Other SBCs, Other Backplanes, Other Chassis, Other Power Supplies, Other Embedded SBCs, Other CompactPCI Devices, Other Servers, Other Network Storage, Other VME, RAD,
CAC, Charles, Eastern, Transition, Other PC/104 Products, Other Subsystems, Other KVM Switches, Other Flat Panels, Other Plasma Engine Computers, Other ACTI Platforms, Other Industrial Peripherals, Other Network Communication Products, IPCMall, PLCPartner, Moxa, Telco, Etasis, Axiom, IEI, Channel Banks, Adtran, PowerSupplyPartner, DelvingWare