The
ACE-C232
includes two ACE-R232A
redundant power modules.
The
two power modules are parallel used.
The
ACE-C232
could be used in ICP Chassis, for example : RACK-305A, PAC-170,
MPC-6010,...etc.
Power
Fault Warning :
In case one power module failed, the buzzer and LED will act.
After pushing reset button, the buzzer stops and the LED still light
until the failed power module is fixed.
ACE-R232A
230W Redundant
Power Module
Input
: 90V to 130V AC or 180V to 260V AC selectable
Outputs
( Max. Output Power 230W at 30oC )
| Output |
Min.
Load |
Rated
Load |
Max.
Load |
Voltage
Accuracy |
|
+5V
|
4.0A
|
20A
|
25A
|
4.80V
to 5.20V
|
|
+12V
|
1.0A
|
10A
|
12A
|
11.4V
to 12.9V
|
|
-12V
|
0.1A
|
0.5A
|
1A
|
-11.30V
to -12.60V
|
|
-5V
|
0.1A
|
0.5A
|
1A
|
-4.65V
to -5.25V
|
Ripple
and Noise : The peak to peak ripple and noise for +5V output is less
than 50mV, for +/-12V and +5V output is less than 100mV.
Line
Regulation : The line regulation for each output is less +/-1% while
measuring at rated load and +/-10% of 115V AC or 230V AC input voltage
changing.
Load
Regulation : The output voltage load regulation is less than the
following values by changing each output and +/-40% from 60% rated load,
and keep all other outputs at 60% rated load.
-5V : +/-4%
+12V : +/-5% -12V : +/-2%
-5V : +/-2%
Hold
Up Time : >16ms
Power
Good Signal : Go high 100ms to 500ms after all output DC voltages
are within regulation limits.
Efficiency
: 70% typical
Output
Protection : Over Voltage Protection and Short Protection
Operating
Temperature : 0oC ~ 50oC ( derating about 20%
from 30oC to 50oC )
Storage
Temperature : -40oC ~ 85oC
Cooling
: Cooling with a 42CFM forced air
MTBF
: 176,530Hrs
Safety
Standards : UL 1950
CSA22.2 No.234
EN 60950
EMI
Standard : ECC docket 20780 curve " B "
EN55022 class " B "
Connectors
: ECC docket 20780 curve "B"
EN55022 class "B"
Connectors
: DIN 41612 C96
Pin
Assignment :
| Pin
1 |
AC
L |
Pin
11 , 12 , 13 |
+12V |
|
4
|
AC
N |
11 ~
25
|
GND
|
|
9
|
-5V
|
26 ~
31
|
+5V
|
|
10
|
-12V
|
32
|
Power Good
|
|