Input
Table :
| Model |
Input
Range |
Input
Current |
|
ACE-716A
/ 716AP
|
85
~ 135V AC or
180 ~ 265V AC, 47 ~ 440Hz |
4A@115V
AC or
2A@230V AC |
|
ACE-716T
|
-36
~ -72V DC |
6A@-48V
DC |
|
ACE-716C
|
+19
~ +30V DC |
12A@+24V
DC |
-
Output
Table ( at 50oC ) :
|
Model
|
Rated
Load
|
Max.
Output
|
|
+5V
|
+12V
|
-5V
|
-12V
|
+5V
|
+12V
|
-5V
|
-12V
|
|
ACE-716A/716AP
|
18A
|
4A
|
0.5A
|
1A
|
25A
|
10A
|
1A
|
1A
|
|
ACE-716T
|
18A
|
4A
|
0.5A
|
1A
|
25A
|
10A
|
1A
|
1.5A
|
|
ACE-716C
|
18A
|
4A
|
0.5A
|
1A
|
25A
|
10A
|
1A
|
1.5A
|
-
Inrush
Current ( ACE-716A
/ 716AP ) : Not
exceed 15A@115V AC or 30A @230V AC
-
Ripple
and Noise : Less than 100mV
-
Line
Regulation : The line regulation for each outputs are less
than +/-1%, while measuring at rated loading and +/-10% of input
voltage changing
-
Load
Regulation :
-->
ACE-716A / 716AP : Less
than +/-3%@+/-5V and -12V, +/-6%@+12V
--> ACE-716T/C
: Less than
+/-1%@+/-5V and -12V, +/-4%+12V
-
Efficiency
:
--> ACE-716A
/ 716AP : Higher
than 75%
--> ACE-716T/C
: Higher than
70%
-
Hold-up
Time ( ACE-716A/716AP
) : 20ms
(typical)@115V AC
-
Altitude
: 0 ~ 10,000ft
-
Protection
: Over voltage protection. The trip point is around 5.9V
~ 7.0V output
-
Thermal
Protection : Built in 110+/-5oC thermal switch in
HS1
-
Vibration
: 10 ~ 55Hz at 2G 3min. period, 30min. along X, Y and Z axis
-
Impact
: 10G for 20ms once on each X, Y and Z axis
-
Hi-port
isolation :
--> 4300V DC, input to output for one minute
--> 2200V DC, input to ground for one minute
-
MTBF
:
--> ACE-716A
: 188,800 Hours
--> ACE-716T
: 212,050 Hours
--> ACE-716C
: 187,490 Hours
-
Safety
: Meets UL 478, 1012, 1950; CSA 22.2 No. 234, VDE EN60 950
-
EMI
:
--> Meets FCC docket 20780 curve "A", EN50081-2 :
CISPR22 "A"
--> Harmonic EN 61000-3-2 for ACE-716AP
-
EMS
Standard ( Design to meet the following limits ) :
--> EN 50082-2
--> IEC 801-1 8KV (Air Discharge ) criteria B ( ACE-716A/716AP
)
--> IEC 801-3, 10V/M criteria A
--> IEC 801-4, 2KV criteria B ( ACE-716A/716AP )
--> IEC 801-5, 2KV criteria B ( ACE-716A/716AP )
-
Built-in
ball bearing cooling fan
-
Operating
Temperature : -20o ~ 70oC ( Derating
curve will occur 50o ~ 70oC)
-
Storage
Temperature : -20o ~ 85oC
-
Dimensions
: 97(W) x 40.5(H) x 198(D)mm; ( 3.8" x 1.6" x
7.8" )