Notice: You have reached an older version of the Vox Technologies website.

We still carry the products and offer the services on this version of the site, but many features and services are out of date.

To be directed to our new portals, please select from the below:

Please do not hesitate to contact us directly at +1-972-234-4343 or (toll free) 1-800-941-0322.


ICP Electronics
ITouch Partner
Lucent Partner
Marconi Partner
Nortel Partner
RAD Partner
Telco Partner
Tellabs Partner
VoxTechnologies 3Com Partner
Adtran Partner
Alcatel Partner
CA Partner
ChannelBank
Cisco Systems Partner
Eastern Partner
Enterasys Partner
Extreme Partner
Larscom Partner Kentrox Partner

Source for VMEbus, PMC Modules, CompactPCI, Single Board Computers, Rackmount Servers, and Rackmount Chassis

Ordering Form   

Unit of Measurement Converter

 

Carrier Access Series

abiisnmp.jpg (13847 bytes)Access Bank II
Access Bank II/SNMP

Quick Resources: PDF Brochures -- Product Guides

Operational Description

The Access Bank® II includes two T1 network interfaces with fully-integrated CSU/DSUs for over 3.0 Mbps of total bandwidth. The dual T1 interfaces can be utilized for any combination of voice and high-speed data services, automatic protection of T1 network connections, and drop and insert applications.

Six different types of 12-channel and 4+8 channel telephone line interface circuit cards provide a wide variety of analog line services such as FXS, FXSDN, SPOTS, PLARD, BRFXS, FXO, DPO, DPT, E&M, and TO. The Access Bank II operates with high-speed modems and automatically adapts to different line conditions, providing a clear, echo-free transmission path.

In-service maintenance capabilities include hot swap line cards, line channel LEDs and fuseless protection of all line interfaces. Deployment time is minimized with simple configuration information printed on the case, along with DIP switches for manual activation of settings and test functions while on-site.

Configuration and tests are available through several management software options. For configuring, monitoring, and testing, a Windows®-based GUI program is included. In addition, an embedded SNMP Agent is accessed via a 10Base-T Ethernet port. Remote T1 management is available from Carrier Access' Access Navigator™, without using customer bandwidth.

Carriers and end-users install the Access Bank II for multi-line voice plus high-speed data services, long distance access, branch office voice and data connectivity, protection of mission critical T1s and the integration of fax, modem, high-speed data and digital PBX connections on access T1s.

Access Bank II Features and Advantages:

Features Advantages
2 T1s with 2 CSUs (3.0 Mbps total) More T1 bandwidth to network, T1 automatic protection, T1 drop to PBX, digital cross connect
T1, V.35, RS-232 and optional SDSL data interfaces Data wiring and service demarcation options to solve any data deployment need
Ethernet, RS-232, and T1 Facilities Data Link (FDL) management connectivity Provides both enterprise and remote carrier management of voice and data service delivery
Built-in T1 and data bit error testing Remote service testing without extra equipment
Fuseless line protection, fanless cooling and solid-state signaling Increases service availability and reduces truck rolls
Low power consumption with -48 VDC inputs and A.C. charger Economical eight hour battery backup option increases service availability
Compact size, one rack unit Saves space in wall or rack-mounted service installations
Wide variety of voice service line interface with programmable signaling and tests Offers all voice service types for carrier and enterprise applications

Optional Installation Kit

SpeedwayTM Installation Kit (for Access Bank or Access Exchange units)

Your installation is literally a snap. This Kit uses locking tabs and pins, versus screws, to install up to two Access Bank or Access Exchange units. Customer installation tests have shown up to a 75% reduction in installation time, as well as up to a 45% smaller footprint.

Technical Specifications

T1 Interface

  • Two T1s terminating 3.072 Mbps of usable bandwidth
  • Fully-integrated intelligent CSUs support diagnostic functions and DS1 or DSX-1 signal levels from 0 to -30dB with built-in CSU network loopbacks and QRSS for BERT fault isolation
  • D4 (SF) and ESF framing and conversion between T1 lines AMI or B8ZS line coding and conversion
  • Terminates and time slot interexchanges 24 analog interfaces and two data interfaces from either or both T1 lines
  • Clock source is internal enhanced Stratum 4 (master) or synchronized from either T1 line (Line1 or Line2)

Analog Interfaces

  • FXS 12-channel card - Supports CLASS® features, such as distinctive ringing and caller ID. Provides loop-start, ground-start, E&M signaling conversion and calling party disconnect.
  • BRFXS/DPO 12-channel card - Operates as a Battery Reversal FXS loop-start card (BRFXS) or a Dial Pulse Origination (DPO) card. Supports CLASS features, such as distinctive ringing and caller ID.
  • FXO/DPT 12-channel card - Operates in FXO loop or ground start signaling or Dial Pulse Terminate (DPT) signaling. CLASS features are supported. Provides E&M signaling conversion and calling party disconnect.
  • 4 FXO + 8 FXS - Supports 4 FXO/DPT circuits and 8 FXS circuits as described above.
  • 4-Wire E&M/TO 12-channel card - Supports signaling types I, II, IV or V. Uses up to four signaling and transmission pairs per channel (E/M, SG/SB, T/R and TI/RI)
  • 2-Wire E&M/TO 12-channel card - Supports signaling types I, II, IV or V. Uses up to three signaling and transmission pairs per channel (E/M, SG/SB and T/R).
  • Full compatibility with V.34 (33.6Kbps) and V.90 (56Kbps) modems.
  • Patented automatic two-wire analog impedance adjustment adapts to various modems and line lengths.

User Programmable Digital Cross Connect and Multiplexing Functions

  • User-programmable bandwidth allocations of voice and data
  • Two T1/CSU DS0 Digital Cross Connect (DCS) functionality - three frames maximum (0.375ms) T1 to T1 delay
  • One T1/CSU plus one T1/CSU D&I port
  • Enables ESF to D4 (SF) conversion for PBXs with T1 interfaces
  • T1 line fault alternate route remapping to second active T1 line without dropped connections (1x1 T1 single-ended Automatic Protection Switching - APS)

Data Interfaces

  • Synchronous V.35 DCE data to 1.536 Mbps in Nx56 Kbps or Nx64 Kbps steps in any channel combination from 1 to 24 Carrier Access P/N 005-0008 male, Carrier Access P/N 005-0014 female).
  • SDSL data option to 1.1 Mbps delivers full bandwidth over 12K feet with UTP wiring.
  • Synchronous RS-232 data at 56 or 64 Kbps (requires optional cable Carrier Access P/N 005-0001).
  • Asynchronous point-to-point RS-232 data at 9.6, 19.2, 38.4, and 57.6 Kbps (requires optional cable Carrier Access P/N 005-0001).
  • Built-in V.54 data loop code generation and detection for V.35 connection.

Management

  • RS-232 port and cable for local Windows® -based GUI management included
  • SNMP and Telnet management via Ethernet port
  • Remote Facilities Data Link management over ESF T1 connections to Carrier Access' Access Navigator products
  • Front panel T1 test switches and status LEDs
  • Back panel analog channel option, test switches, and status LEDs

Alarms

  • Dial-out notification over modem attached to RS-232 management port. SNMP alarm traps over Ethernet.

Compliance

  • FCC Part 68, CS-03 listed - telephone line interfaces
  • FCC Part 15, Class A Radiated Emissions Control
  • NRTL safety listed: UL 1459, CSA
  • National Electrical Code 1996 safety requirements
  • ANSI/TIA T1.403 and AT&T 54016 ESF reporting on Facility Data Link
  • AT&T 62411 (Stratum 4 enhanced T1 CPE)
  • NEBS Level 1

Power

  • -48 VDC @ 1A input from battery source
  • 115Vac/75W power converter (Carrier Access P/N 730-0124)
  • Optional 220Vac/50Hz to -48Vdc converter module for international applications (Carrier Access P/N 730-0083)
  • Solid-state (fuseless) overvoltage and overcurrent protection

CPE Battery Backup System

  • Optional 120Vac to -48Vdc power converter/battery charger (Carrier Access P/N 730-0116) and battery unit (Carrier Access P/N 730-0114) for up to eight hours of uninterruptible power protection

Environmental

  • Normal operating temperature: 32° F to 122° F (0° to 50° C)
  • Solid-state over-temperature protection prevents damage to the unit
  • Relative humidity: 0 to 95%, non-condensing

Physical

  • Dimensions: 17" x 17.75" x 1.75" (43.2cm x 45.1cm x 4.5cm)
  • Weight: 14.5 lbs. (6.6 kg) fully loaded
  • Power converter/battery charger unit: 4" x 5" x 3.25", 6 lbs.
  • Battery backup unit: 17" x 6.25" x 3", 30 lbs.
  • Flush wall mount, desktop, or 19" rack mount (multi-function brackets included)
  • 24 units can be mounted in a 7ft., 23" standard rack
  • Optional heavy-duty 19" (Carrier Access P/N 710-0041) or 23" (Carrier Access P/N 710-0130) rack mounting brackets with adjustable front-to-back offset
  • Optional Trimount bracket for wall mounting of three Access Banks and power converters (Carrier Access P/N 710-0002)
  • Optional Speedway Installation Kit (Carrier Access P/N 710-0007) [At Optional Speedway Installation Kit, insert link to Kit Product Page.

CompactPCI, Embedded SBCs, Flat panel Displays, Industrial Chassis, IndustrialPC Peripherals, Industrial Power Supplies, Backplanes, Single Board Computers, Rackmount Servers, Network Communication, Open Frame Panel Computer, PC/104, Flash Disk, CTI, RAID Back to Home CompactPCI, Embedded SBCs, Flat panel Displays, Industrial Chassis, IndustrialPC Peripherals, Industrial Power Supplies, Backplanes, Single Board Computers, Rackmount Servers, Network Communication, Open Frame Panel Computer, PC/104, Flash Disk, CTI, RAIDE-Mail   VoxTechnologies Corp. - Industrial Computer Leader
Tel:
972-234-4343 Fax: 972-234-4295 Toll-Free: 1-888-568-6224
 

An Industrial Partner 1999-2002. All rights reserved.


CompactPCI, Embedded SBCs, Flat panel Displays, Industrial Chassis, IndustrialPC Peripherals, Industrial Power Supplies, Backplanes, Single Board Computers, Rackmount Servers, Network Communication, Open Frame Panel Computer, PC/104, Flash Disk, CTI, RAID Back to Home CompactPCI, Embedded SBCs, Flat panel Displays, Industrial Chassis, IndustrialPC Peripherals, Industrial Power Supplies, Backplanes, Single Board Computers, Rackmount Servers, Network Communication, Open Frame Panel Computer, PC/104, Flash Disk, CTI, RAID E-Mail

VoxTechnologies Corp. - Industrial Computer Leader
Tel:
1-972-234-4343 Fax: 1-972-234-4295 Toll-Free: 1-888-568-6224

For over a decade, VoxTechnologies has been a leading source of industrial computers and complete system products for the O.E.M. and Systems Integrator. Our primary goal is to provide a solution source for engineers that have the challenging task of interfacing and controlling the real world.

Telephone: 1-972-234-4343 General Info: info@voxtechnologies.com Sales Info: sales@voxtechnologies.com
 
We accept all major credit cardsRelated Links Adtran AFC CAC Larscom Metrobility Moxa NetAnchor
VTC SBCs, VTC Chassis, VTC Backplanes, VTC CompactPCI, VTC Power Supplies, VTC Peripherals, Other SBCs, Other Backplanes, Other Chassis, Other Power Supplies, Other Embedded SBCs, Other CompactPCI Devices, Other Servers, Other Network Storage, Other VME, RAD,
CAC, Charles, Eastern, Transition, Other PC/104 Products, Other Subsystems, Other KVM Switches, Other Flat Panels, Other Plasma Engine Computers, Other ACTI Platforms, Other Industrial Peripherals, Other Network Communication Products, IPCMall, PLCPartner, Moxa, Telco, Etasis, Axiom, IEI, Channel Banks, Adtran, PowerSupplyPartner, DelvingWare
Archives
Send mail to webmaster@voxtechnologies.com with questions or comments about this web site.
Copyright © 1999 VoxTechnologies Corporation- An Industrial Partner
Last modified: November 30, 2002   Proud Sponsor of Dallas Jazz