| Output Voltage: |
Proportional to
input voltage: 230 Vdc at 85 Vac, 370 Vdc at 264 Vac |
| Output Power: |
600 W max. at
105-264 Vac500 W max. at 85-264 Vac |
| Input
Voltage/Current: |
85-132 Vac, 47-63
Hz, 10 A max.170-264 Vac, 47-63 Hz, 5 A max. Automatically
switches between low and high input voltage ranges |
| Auxiliary Output: |
+12 Vdc at 50 mA
max., can tolerate short circuit for up to 5 sec. |
| Power Factor: |
0.60 typical |
| Inrush Current: |
40 A max. |
| Efficiency: |
97% typical |
| Holdup Time: |
20 msec min. from
input power failure until AC OK signal goes low, full load and
115 Vac |
| AC Fail Warning: |
5 msec continued
operation after AC OK signal drops |
| Output Ripple: |
25 V pk-pk max. |
| Turn-on Time: |
500 msec max. until
Load Enable signal goes high |
| Input Fuse: |
Internal one-pole
10A NTD fuse |
| Output Short
Protection: |
External fuses
required at dc-dc converters |
| Leakage Current: |
1.0 mA max. at 240
Vac |
| Hipot: |
2200 Vdc |
|
 |
 |
|
|
|
|
|
| On/Standby Switch: |
Connect to return
with front panel switch to begin operation |
| Return: |
Signal return (can
be connected to system ground) |
| AC OK: |
TTL high indicates
input and output voltages OK |
| +12 Vdc Aux: |
+12 Vdc at 50 mA
max. |
| Load Enable: |
+12 Vdc active high
for controlling dc-dc converters(470W
output impedance. Load enable signal must be used to activate
load for proper AC inrush limit operation) |
|
|
|
|
 |
|
| Operating
Temperature: |
-20°C to 70°C |
| Storage Temperature: |
-40°C to 85°C |
| Size/Weight: |
1.5"H x
4.0"W x 6.0"L, 1.0 lb. |
| Shock and Vibration: |
Mil-Hdbk 810E |
| Humidity: |
95% non-condensing |
| Mating Connector: |
5 pin control
connector AMP part no. 102241-3 |
|
|