Designed for 1U Server Appliance Product
- Input Range :
90V AC~264V AC full range (ACE816AP/ACE916AP)
95V AC~132V AC, 180V AC~264V AC manual switch (ACE816A/ACE916A)
- ACE916A:
The output of +5V and +12V total output shall not exceed 146.4W, Total
output maximum 150W
ACE816A: The output of +3.3V and +5V total output shall not exceed 61.5W,
The +3.3V and +5V, +12V total output shall not exceed 136.4W, Total output
maximum 150W
ACE916AP: The output of +12V and +5V total output shall not exceed 145W,
Total output maximum 150W
ACE816AP: The output of +3.3V and +5V total output shall not exceed 85W,
Total output maximum 150W
- ACE815T Output Rating
#+5V, +3.3V and +12V total output not exceed 135W
- ACE815C Output Rating
#+5V, +3.3V and +12V total output not exceed 84W
- Hold-up time :
17ms min. (AC Input Power Supply only)
- Efficiency :
68% typ. (ACE816AP/916AP); 72% typ. (ACE816A/916A)
- Protection :
Over Voltage/Load
Protection and Short Circuit Protection
- TTL signal compatible power good signal
- Vibration :
10-55Hz at 2G 3min. period, 30 min. along X, Y and Z axis.
- Shock :
10G for 11ms once on each X, Y and Z axis.
- Built-in cooling fan
- Power Connector:
ATX (ACE816A/AP/815T/815C) ; P8/P9 (ACE916A/AP)
- MTBF :
100,000hrs at 25șC
- Safety
: Meets UL 1950, CSA 22.2 Level 3,TUV, CCC.
- EMI :
Meets FCC class "B",EN55022 class "B" Meets Harmonic
EN61000-3-2 (ACE815AP, ACE915AP)
- EMS Standard :
meet
- IEC 801-2 8KV(Air Discharge)
- IEC 801-3 3V/M criteria A
- IEC 801-4,2KV criteria B
- IEC 801-5,2KV criteria B
- Operating Temp. :
0-50șC
|
|





- ACE816A
150W ATX Power Supply
- ACE816AP
150W ATX Power Supply full Range with PFC function
- ACE815T
150W 48VDC ATX Input Power Supply
- ACE815C
100W 24VDC ATX Input Power Supply
- ACE916A
150W AT Power Supply
- ACE916AP
150W AT Power Supply full Range with PFC function
|