Notice: You have reached an older version of the Vox Technologies website.

We still carry the products and offer the services on this version of the site, but many features and services are out of date.

To be directed to our new portals, please select from the below:

Please do not hesitate to contact us directly at +1-972-234-4343 or (toll free) 1-800-941-0322.


ICP Electronics
ITouch Partner
Lucent Partner
Marconi Partner
Nortel Partner
RAD Partner
Telco Partner
Tellabs Partner
VoxTechnologies 3Com Partner
Adtran Partner
Alcatel Partner
CA Partner
ChannelBank
Eastern Partner
Enterasys Partner
Extreme Partner
Larscom Partner Kentrox Partner

Source for VMEbus, PMC Modules, CompactPCI, Single Board Computers, Rackmount Servers, and Rackmount Chassis

ACER20A ] ACER20C ] ACER20T ]

Home
Up
Search
Industrial Products
ACE709CX
ACE713APM
ACE810V
ACE818C
ACE828V
ACE830CU1
ACE830TU1
ACE830VU1
ACE840APU2
ACE850AP
ACE903A
ACE906V
ACEN023C
ACE1010A
ACE1020A
ACE540A
ACE716
ACE723
ACE815C
ACE815T
ACE816A
ACE816AP
ACE828
ACE828M
ACE830
ACE830APU1
ACE832A
ACE832AP
ACE832APS
ACE840A
ACE840AP
ACE845
ACE855
ACE865
ACE870
ACE890
ACE905A
ACE916A
ACE916AP
ACE916V
ACE925A
ACE920A
ACE925M
ACE925T
ACE932T
ACE935A
ACE932A
ACE930AP
ACE940AP
ACEC232
ACER Series
ACER30A
ACER30AP230V
ACERC02
ACERC03
ACERC04
ACERC12

ACER20A                                         
AC/DC Input Redundant Power Supply Module

 

 

  • Input Table :
  • Output Table : (at 40ºC )
  • Ripple and Noise : Less than 140mV@+12V and 1%@Others
  • Line Regulation : Less than +/-2%@+12V, +/-1%@Others
  • Load Regulation :
  • Efficiency : Higher than 65%
  • Hold-up Time (ACER20A):14ms (typical)@115V AC
  • Altitude : 0 ~ 10,000ft
  • Protection :
    - Over voltage protection : The trip point is around 5.7V ~ 7.0V output
    - Short circuit protection
    - Thermal protection with built-in 110+/-5ºC thermal switch in HS1
  • Power Fail Signal : The power fail signal will go low at least 0.5ms before any of the output voltages fall below the regulation limits
  • Power Fail Alarm : It will turn the red LED and beeper when power fail
  • Power Sharing & Redundancy :
    These power have power sharing and redundancy capability. When doing that the power share line (Pin 32) must connect with each other
  • Vibration : 10 ~ 55Hz at 2G 3min. period, 30 min. along X, Y and Z axis
  • Impact : 10G for 20ms once on each X, Y and Z axis
  • Built-in cooling fan
  • MTBF :
    - ACER20A : 131,547 Hours
    - ACER20T : 141,323 Hours
    - ACER20C : 146,383 Hours
  • Safety : Meets UL 1950; CSA 22.2 No. 234, VDE EN 60950
  • EMI : Meets FCC docket 20780 curve "B", EN55022 class "B"
  • EMS Standard (Designed to meet the following limits) :
    - IEC 801-2 8KV (Air Discharge) criteria B
    - IEC 801-3, 10V/M criteria A
    - IEC 801-4, 2KV criteria B
    - IEC 801-5, 2KV criteria B (ACER20A)
  • Operating Temperature : -20ºC ~ 70ºC
    (Derating curve will occur 45ºC ~ 70ºC)
  • Storage Temperature : -40ºC ~ 75ºC


ACER20T/C


ACER20A


Reae View

  • ACER20A
    AC input redundant power supply module
  • ACER20T
    -48V DC input redundant power supply module
  • ACER20C
    +24V DC input redundant power supply module