- Input Table :
- Output Table : (at 40ºC
)
- Ripple and Noise :
Less than 140mV@+12V and 1%@Others
- Line Regulation :
Less than +/-2%@+12V,
+/-1%@Others
- Load Regulation :
- Efficiency :
Higher than 65%
- Hold-up Time (ACER20A):14ms
(typical)@115V AC
- Altitude :
0 ~ 10,000ft
- Protection :
- Over voltage protection : The trip point is around 5.7V ~
7.0V output
- Short circuit protection
- Thermal protection with built-in 110+/-5ºC thermal switch in
HS1
- Power Fail Signal :
The power fail signal will go low at least 0.5ms before any of
the output voltages fall below the regulation limits
- Power Fail Alarm :
It will turn the red LED and
beeper when power fail
- Power Sharing &
Redundancy :
These power have power sharing and redundancy capability. When
doing that the power share line (Pin 32) must connect with
each other
- Vibration :
10 ~ 55Hz at 2G 3min. period, 30 min.
along X, Y and Z axis
- Impact :
10G for 20ms once on each X, Y and Z
axis
- Built-in cooling fan
- MTBF :
- ACER20A : 131,547 Hours
- ACER20T : 141,323 Hours
- ACER20C : 146,383 Hours
- Safety :
Meets UL 1950; CSA 22.2 No. 234, VDE
EN 60950
- EMI :
Meets FCC docket 20780 curve "B", EN55022 class
"B"
- EMS Standard (Designed
to meet the following limits) :
- IEC 801-2 8KV (Air Discharge) criteria B
- IEC 801-3, 10V/M criteria A
- IEC 801-4, 2KV criteria B
- IEC 801-5, 2KV criteria B (ACER20A)
- Operating Temperature :
-20ºC ~ 70ºC
(Derating curve will occur 45ºC ~ 70ºC)
- Storage Temperature :
-40ºC ~ 75ºC
|

ACER20T/C
ACER20A
Reae View


- ACER20A
AC input redundant power supply module
- ACER20T
-48V DC input redundant power supply module
- ACER20C
+24V DC input redundant power supply module
|