- Input / Output Table :
(at 50șC)

ACE890AP: min load + 5VDC/ 1.5A, + 12VDC, -12VDC/ 0.05A
- Ripple and Noise :
Less than +5V@50mV, +/-12V@100mV Less than +5V@100mV, -12V@150mV,
-12V@200mV (ACE890AP)
- Line Regulation :
The line regulation for each output is less than +/-1%,
while measuring at rated loading and +/-10% of input voltage changing
- Load Regulation :
Less than +/-1%@+5V and +/-5%@+/-12V
- Efficiency :
Higher than 70%
- Hold-up Time
(ACE890A/890AP) : 16ms (typical)@115V AC
- Protection :
Over voltage protection. The trip point is around 5.7V~7.0V
output
- Operating Temperature :
-20șC ~70șC (Derating curve will occur 50șC ~70șC)
- Storage Temperature :
-20șC ~85 șC
- Altitude :
0~10,000ft
- MTBF :
- ACE890A : 268,358 Hours
- ACE890P : 265,827 Hours
- ACE890T : 269,884 Hours
- ACE890C : 252,383 Hours
- ACE890V : 245,424 Hours
- ACE890AP : 50,000Hours
- Safety :
Meets UL 1950, CSA 22.2 No. 234, VDE EN 60 950
- EMI :
- Meets FCC docket 20780 curve "B", EN55022 "B"
- Harmonic EN 61000-3-2 for ACE890AP
- EMS Standard
(Designed to meet the following limits) :
- IEC 801-2 15KV (Air Discharge)
- IEC 801-3, 10V/M
- IEC 801-4, 2KV
- IEC 801-5, 2KV
- Dimensions :
89(W) x 39(H) x 152.4(D)mm; (3.5" x 1.5" x 6")
 |
|



CB8901
CB8902 CB8903

- ACE890AP
AC input 86W industrial PFC power supply
- ACE890A
AC input 90W industrial power supply
- ACE890C
24V DC input 90W industrial power supply
- ACE890P
100V DC input 90W industrial power supply
- ACE890T
48V DC input 90W industrial power supply
- ACE890V
12V DC input 75W industrial power supply
- CB8901
DC output cable for backplane (P8/P9 type)
and HDD/FDD, 40cm
- CB8902
DC output cable for CPU card (271-08TS) and HDD/FDD, 40cm
- CB8903 DC
output cable for NOVA series SBC (Molex
26-60-4080) and HDD/FDD, 40cm
|