Input
Table :
| Model |
Input
Range |
Input
Current |
|
ACE828A/830AP
|
90
~ 130V AC or 180 ~ 260V AC,
47 ~ 63Hz ( Auto-Switch ) |
|
|
ACE828C
|
+18
~ +32V DC |
5A@24V
DC |
|
ACE828T
|
-40
~ 72V DC |
10A@-48V
DC |
-
Output
Table : ( at 40oC )
|
Model
|
Rated
Load
|
Max
Output
|
| +5V |
+12V |
-12V |
-5V |
+3.3V |
+5Vsb |
+5V |
+12V |
-12V |
-5V |
+3.3V |
+5Vsb |
|
ACE830AP
|
30A |
6A |
0.5A |
0.5A |
1A |
1A |
35A |
10A |
1A |
1A |
20A |
1.5A |
|
ACE828A
|
25A
|
10A |
0.5A |
0.5A |
8A |
0.72A |
30A |
15A |
2A |
1A |
15A |
1.2A |
|
ACE828C
|
25A
|
7A |
1A |
0.5A |
8A |
0.72A |
30A |
15A |
2A |
1A |
15A |
1.2A |
|
ACE828T
|
25A |
7A |
1A |
0.5A |
8A |
0.72A |
30A |
15A |
2A |
1A |
15A |
1.2A |
-
Ripple
and Noise : Less than 50mV@+5V and +3.3V; 100mV@Others
-
Line
Regulation : The line regulation for each outputs are
less than +/-1%
-
Load
Regulation :
|
Model
|
+5V
|
+12V
|
-12V
|
-5V
|
+3.3V
|
+5Vsb
|
|
ACE830AP
|
<+/-1%
|
<+/-1%
|
<+/-1%
|
<+/-1%
|
<+/-1%
|
<+/-1%
|
|
ACE828A
|
<+/-3%
|
<+/-5%
|
<+/-2%
|
<+/-2%
|
<+/-2%
|
<+/-3%
|
|
ACE828C
|
<+/-3%
|
<+/-5%
|
<+/-2%
|
<+/-2%
|
<+/-2%
|
<+/-1%
|
|
ACE828T
|
<+/-3%
|
<+/-5%
|
<+/-2%
|
<+/-2%
|
<+/-2%
|
<+/-1%
|
-
Output
Power : Total Combined output power on the +3.3V and +5V rails
is 150W
-
Efficiency
: Higher than 65%
-
Hold-up
Time ( ACE828A/830AP
) : 20ms
(typical)@115V AC
-
Altitude
: 0 ~ 10,000ft
-
Protection
:
--> Over voltage protection : The trip point is
around 5.7V ~ 7.0V output
--> Short circuit protection
-
Vibration
: 10 ~ 55Hz at 2G 3min. period, 30min. along X, Y and Z axis
-
Impact
: 10G for 20ms once on each X, Y and Z axis
-
Built-in
ball bearing cooling fan
-
MTBF
:
--> ACE828A
: 101,379 Hours
--> ACE828C
: 121,233 Hours
--> ACE828T
: 112,112 Hours
-
Safety
: Meets UL 1950; CSA 22.2 No. 234, VDE EN 60 950
-
EMI
:
--> Meets FCC class "B", EN55022 class
"B"
--> Harmonic EN 61000-3-2 for ACE830AP
-
EMS
Standard ( Design to meet the following limits ) :
--> IEC 801-2 8KV ( Air Discharge )
--> IEC 801-3, 3V/M criteria A
--> IEC 801-4, 2KV criteria B
--> IEC 801-5, 2KV criteria B
-
Operating
Temperature : -20o ~ 70oC ( Operating
curve will occur 40o ~ 70oC)
-
Storage
Temperature : -40o ~ 75oC