Input
Table : 90V - 264VAC (
ACE815AP )
95V - 132VAC, 180 - 264VAC, manual switch (
ACE815A )
-
ACE815A/815AP
Output Rating
|
Output
|
Nominal
|
Regulation
|
Ripple/Noise
|
Min.
|
Max.
|
|
1
|
+3.3V
|
+/-5%
|
100mV
|
1A
|
10A
|
|
2
|
+5V
|
+/-5%
|
150mV
|
2A
|
14A
|
|
3
|
+12V
|
+/-5%
|
200mV
|
0.6A
|
4A
|
|
4
|
-5V
|
+/-10%
|
200mV
|
0.05A
|
0.2A
|
|
5
|
-12V
|
+/-10%
|
250mV
|
0.05A
|
0.2A
|
|
6
|
+5VSB
|
+/-5%
|
200mV
|
0A
|
1.5A
|
Total
Output of +3.3V and +5V shall not exceed 90W.
-
Hold-up
time : 16ms min.
-
Efficiency
: 65% typ.
-
Protection
: Over
Voltage / Load Protection and Short Circuit Protection
-
TTL
signal compatible power good signal
-
Vibration
: 10 ~ 55Hz
at 2G 3min. period, 30min. along X, Y and Z axis
-
Shock
: 10G for 11ms once on each X, Y and Z axis.
-
Built-in
ball bearing fan
-
MTBF
: 100,000hrs at 25oC
-
Safety
: Meets UL
1950, CSA 22.2 Level 3, TUV
-
EMI
:
--> Meets FCC class
"B", EN55022 class "B"
--> Meets Harmonic EN61000-3-2 (
ACE815AP )
-
EMS
Standard : meet
--> IEC 801-2 8KV ( Air Discharge )
--> IEC 801-3, 3V/M criteria A
--> IEC 801-4, 2KV criteria B
--> IEC 801-5, 2KV criteria B
-
Operating
Temp. : 0o
~ 50oC