- Input :
Voltage : 85 ~ 264V AC
- Output :
-2A@24V DC, 50șC with 20CFM air cooling
-1.7A@24V DC, 50șC with free air cooling
- Load Regulation :
Less than +/-1% by changing the output
- Efficiency :
Higher than 70%
- Hold-up Time :
20ms (typical)@115V AC
- Protection :
Over voltage protection.
The trip point is around 26.2V ~ 31V output
- Operating Temperature :
-20șC ~ 70șC
(Will derate the output to 70% when operating at 70șC)
- Storage Temperature :
-40șC ~ 85șC
- Altitude :
0 ~ 10,000ft
- MTBF :
396,220 Hours.
- Safety :
UL 1950, CSA 22.2 No. 234, VDE EN 60950
- EMI :
FCC docket 20780 curve "B", EN55022
- EMS Standard :
- EN-50082-1
- IEC 801-2 8KV (Air Discharge) criteria B
- IEC 801-3, 3V/M criteria B
- IEC 801-4, 2KV criteria B
- IEC 801-5, 2KV criteria B
 |
|



- ACE540A
24V DC Output Industrial Power Supply
|