Download:
Datasheet
In-Depth
Product Image
Click
here to download the Acrobat Reader
|
|
Input Table :
90V - 264VAC
Output Rating
|
Output |
1 |
|
Nominal |
+3.3V |
|
Regulation |
+/-5% |
|
Ripple/Noise |
100mV |
|
Min. |
1A |
|
Max. |
10A |
|
Output |
2 |
|
Nominal |
+5V |
|
Regulation |
+/-5% |
|
Ripple/Noise |
150mV |
|
Min. |
2A |
|
Max. |
14A |
|
Output |
3 |
|
Nominal |
+12V |
|
Regulation |
+/-5% |
|
Ripple/Noise |
200mV |
|
Min. |
0.6A |
|
Max. |
4A |
|
Output |
4 |
|
Nominal |
-5V |
|
Regulation |
+/-10% |
|
Ripple/Noise |
200mV |
|
Min. |
0.5A |
|
Max. |
0.2A |
|
Output |
5 |
|
Nominal |
-12V |
|
Regulation |
+/-10% |
|
Ripple/Noise |
250mV |
|
Min. |
0.5A |
|
Max. |
0.2A |
|
Output |
6 |
|
Nominal |
+5VSB |
|
Regulation |
+/-5% |
|
Ripple/Noise |
200mV |
|
Min. |
0A |
|
Max. |
1.5A |
Total Output of +3.3V and +5V shall not exceed 90W.
Hold-up time : 16ms min.
Efficiency : 65% typ.
Protection : Over Voltage / Load Protection and Short Circuit
Protection
TTL signal compatible power good signal
Vibration : 10 ~ 55Hz at 2G 3min. period, 30min. along X, Y and Z
axis
Shock : 10G for 11ms once on each X, Y and Z axis.
Built-in ball bearing fan
MTBF : 100,000hrs at 25oC
Safety : Meets UL 1950, CSA 22.2 Level 3, TUV
EMI :
--> Meets FCC class "B", EN55022 class "B"
--> Meets Harmonic EN61000-3-2
EMS Standard : meet
--> IEC 801-2 8KV ( Air Discharge )
--> IEC 801-3, 3V/M criteria A
--> IEC 801-4, 2KV criteria B
--> IEC 801-5, 2KV criteria B
Operating Temp.
0o ~ 50oC
|