CONTROLLER SPECIFICATIONS
RISC Processor........................i960RM; i960RS**
Speed.................................100MHz
Dual AD-dress..........................Supported
PCI...................................2.2
ACPI..................................Compliant
Flash.................................1MB
Cache.................................16MB**, 32MB or 64MB
PCI Bus...............................32 bit, 33MHz
PCI Hot Plug..........................Yes
PHYSICAL SPECIFICATIONS
PCI card..............................Half length;
Low Profile*(2U Form Factor)
Power Requirements....................+5.0v (+-5%) 3.5 A (max); 17.5 watts
Temperature...........................0 to 55º C
MTBF..................................200,000 hrs.
Warranty..............................Three years
Certification.........................FCC Class B, CE, UL, PC 99, Windows NT, Novell
SCO OSR/ UnixWare, Solaris 7, x86
SCSI SPECIFICATIONS
Supports SCSI1, SCSI2, Ultra SCSI, Ultra2 SCSI and Ultra 160 SCSI devices
o Full support for Low Voltage Differential (LVD) devices
o Up to 160MB/sec burst data rate per channel
o Automatic SCSI bus termination
o Disconnect/Reconnect
o 256 tagged commands per controller
o Automatic sector remapping
o Ultra 160 SCSI (LVD), cable lengths up to 25 meters for two devices or 12 meters for 15 devices
o One Wide Ultra 160 SCSI LVD channel
o Supports up to 1.08TB (using 72GB drives)
o 15 devices per controller
RAID FAULT TOLERANT AND FLEXIBILITY FEATURES
o RAID levels 0, 1, 0+1, 3, 5, 10, 30, 50, JBOD
o Transparent disk drive rebuild
o Mylex Online RAID expansion (M.O.R.E.)
o Up to 32 controllers per system (NT)
o Logical drive size of 2TB, 32 logical controller/ drives
o Immediate RAID Availability; background initialization
o Variable stripe size per controller
o Variable cache line size per controller
o Up to eight non-disk devices per controller
o Drive roaming during power off
o SAF-TE and SES enclosure management
o Automatic error recovery
o Write-through or write-back cache support
o Automatic detection of failed drives
o Automatic rebuild of hot spare drive
o Hot drive swapping support
o Support for SMART capable drives
o Controller parameters stored on disk and NVRAM
o RAID configuration stored on disk
o PCI Hot Plug (Windows 2000, Windows NT and NetWare)
RAID MANAGEMENT o Global Array Manager - Client server GUI interface - Create, manage, expand and monitor programs - Error statistics and performance information o RAID EzAssist: BIOS resident - RAID configuration - Automated menus for easy configuration - Custom menus for advanced users SYSTEM DRIVER SUPPORT o Windows 2000 - Professional edition and enterprise edition o Windows NT server 4.0 and enterprise edition o NetWare 4.11 & above, 5.x and SMP with NWPA o SCO UnixWare 2.1, 7.0, UNIX OSR 5.0.4, 5.0.5 o DOS 6.x and above o Solaris 7 (x86) o Linux AcceleRAID 170 MXACC170-1-32NB |
|