FUNCTIONAL SPECIFICATIONS |
 |
 |
 |
|
|
Formatted storage capacity |
10 GB |
 |
|
|
Formatted storage capacity |
10,000 MB |
 |
|
|
Form Factor |
2.5-inch x 9.5mm |
 |
|
|
Mounting screws |
#6-32UNC |
 |
|
|
Disks |
1 |
 |
|
|
Heads (read/write) |
2 |
 |
|
|
Track capacity (formatted) |
190,464 to 337,920 bytes |
 |
|
|
Bytes per sector |
512 bytes |
 |
|
|
Cylinders |
28,416 |
 |
|
|
Sectors per track |
372 to 660 |
 |
|
|
Seek time (track to track) |
1.5 typ. milliseconds |
 |
|
|
Seek time (average) |
12 typ. milliseconds (read/write) |
 |
|
|
Seek time (full track) |
22 typ. milliseconds (read/write) |
 |
|
|
Average latency time |
7.14 milliseconds |
 |
|
|
Rotational speed |
4,200 RPM |
 |
|
|
Recording density |
578,017 bits per inch |
 |
|
|
Track density |
50,400 tracks per inch |
 |
|
|
Data transfer rate (to/from media) |
17.4 to 30.7 MB per second |
 |
|
|
Data transfer rate (to/from media) |
139.2 to 245.6 megabits per second |
 |
|
|
Data transfer rate (DMA mode 2) |
16.6 MB per second |
 |
|
|
Data transfer rate (PIO mode 4) |
16.6 MB per second |
 |
|
|
Data transfer rate (UDMA mode 2) |
33.3 MB per second |
 |
|
|
Data transfer rate (UDMA mode 4) |
66.6 MB per second |
 |
|
|
Data transfer rate (UltraATA) |
100 MB per second |
 |
|
|
Recording code |
16/17 MEEPRML |
 |
|
|
Interface |
ATA - 5 |
 |
|
|
Head positioning method |
Rotary VCM Embedded Servo |
 |
|
|
Spindle start time |
5 seconds typical |
 |
|
|
Spindle stop time |
5 seconds typical |
 |
|
|
Data buffer size |
2048 KB |
| |
 |
 |
|
PHYSICAL SPECIFICATIONS |
 |
 |
 |
|
|
Power requirement Voltage |
5V ± 0.5% |
 |
|
|
Ripple |
100 mV P-P |
 |
|
|
Power requirement Spin up |
0.90A maximum |
 |
|
|
Power requirement Read/write |
2.5 W (typical) |
 |
|
|
Power requirement Idle (ready) |
0.75 W (typical) |
 |
|
|
Power requirement Sleep |
0.1 W (typical) |
 |
|
|
Height |
9.5 millimetres |
 |
|
|
Width |
70 millimetres |
 |
|
|
Depth |
100 millimetres |
 |
|
|
Weight |
0.098 kg |
 |
|
|
Ambient temperature (operating) |
5
to 55 degrees C |
 |
|
|
Ambient temperature (non-operating) |
-40 to 65 degrees C |
 |
|
|
Gradient |
20 degrees C per hour |
 |
|
|
Relative humidity (operating) |
8
to 90 % RH (non-condensing) |
 |
|
|
Relative humidity (non-operating) |
5
to 95 % RH (non-condensing) |
 |
|
|
Maximum wet bulb |
29 (Op.)/ 40 (Non Op.) degrees C (non-condensing) |
 |
|
|
Vibration (operating) |
9.8m/s^2 (1.0G) (5 to 400Hz) |
 |
|
|
Vibration (non-operating) |
49m/s^2 (5.0G) (5 to 500Hz) |
 |
|
|
Shock (operating) |
1,715m/s^2 (175G) 2ms |
 |
|
|
Shock (non-operating) |
7,840m/s^2 (800G) 2ms / 1,176m/s^2 (120G) 11ms |
 |
|
|
Altitude (operating) |
-300 to 3,000 metres |
 |
|
|
Altitude (non-operating) |
-300 to 12,000 metres |
 |
|
|
Acoustic noise (at 1 metre idle) |
24 dBA typical |
 |
|
|
Acoustic noise (at 1 metre idle) |
2.4 bels |
| |
 |
 |
|
RELIABILITY SPECIFICATIONS |
 |
 |
 |
|
|
MTBF (Mean Time Between Failures) |
More than 300,000 power on hours |
 |
|
|
MTTR (Mean Time To Repair) |
30 minutes or less |
 |
|
|
Component life (years) |
5 years |
 |
|
|
Component life (hours) |
20,000 power on hours |
 |
|
|
Unrecoverable errors |
1
per 10^13 bits read |
 |
|
|
Seek errors |
1
per 10^6 seeks |
 |
|
|
Start/stop cycles |
300,000 cycles |